Technical data
12.2 Technical data
TP 270, OP 270, MP 270B (WinCC flexible)
Operating Instructions, Edition 03/2004, 6AV6691-1DD01-0AB0
12-7
Backup battery (option)
Type
Lithium battery (Sonnenschein SL2361)
Voltage/Capacity
2)
3.6 V / approx. 1.5 Ah
Service life
Approx. 4 years
2)
All rights reserved
Network connection
MP 270B
OP 270 / TP 270
Type
1 x Ethernet (10/100 Mbit)
Optional via NE 2000-compatible
Ethernet card
Ambient conditions
OP 270 6" / TP 270 6"
MP 270B 6" Touch
MP 270B / OP 270 10" /
TP 270 10"
Installation position
Max. permissible angle of inclination
without external ventilation
Vertical
±
35
°
Vertical
±
35
°
Max. permissible ambient temperature
Operation
Vertical installation
Installation angled from the
perpendicular to max. 35
°
Shipping, storage
0...+50
°
C
0...+35
°
C
-20...+60
°
C
0...+50
°
C
0...+40
°
C
-20...+60
°
C
Shock loading
Operation
Shipping, storage
15 g / 30 ms
25 g / 6 ms
Vibration
Operation
Shipping, storage
0,075 mm (10 - 58 Hz) 1 g (58 - 150 Hz)
3.5 mm (5 - 9 Hz) 1 g (9 - 500 Hz)
Barometric pressure
Operation
Shipping, storage
795
…
1080 hPa
660
…
1080 hPa
Ambient conditions
MP 270B Keys / OP 270
MP 270B Touch / TP 270
Relative humidity
Operation, transport, storage
Max. 90%, no condensation