Device maintenance and repair
7.2 Maintenance
SIMATIC IPC547E
74
Operating Instructions, 02/2014, A5E32317120-AB
7.1.8
Integrating a hot spare hard disk drive in the RAID system
If the hot spare hard disk drive was replaced in a RAID system, the new hot spare hard disk
drive must be integrated in the RAID system once again.
Requirement
A hot spare hard disk drive was replaced in the RAID system, see section "Replacing a
defective hard disk drive in the RAID system (Page 83)".
Procedure
1.
Select "Start" > "Programs" > "Intel Rapid Storage Technology".
The RAID system is configured in the delivery state in such a way that a new hot-spare
drive is automatically integrated.
If the automatic integration of a hard disk in the RAID system is deactivated, the hard disk
must be integrated manually as described below.
2.
Click
"Run Hardware Scan now".
The new hard disk is found and displayed.
3.
Use the right mouse button to mark the new hard disk and select the menu item "Mark
Disk as Spare" in the context menu.
4.
Confirm the alarm in the "Mark Disk as Spare" window with "Yes".
7.2
Maintenance
7.2.1
Maintenance intervals
To maintain high system availability, we recommend the preventative replacement of PC
components subject to wear according to the replacement intervals stated in the table below.
Component
Replacement interval
Drives
3 years
Backup battery
5 years
Device fan
3 years
Filter pad
Depending on the degree of soiling
For information on ordering original replacement parts, see chapter "Service and support
(Page 135)".
Summary of Contents for SIMATIC IPC547E
Page 4: ...Preface SIMATIC IPC547E 4 Operating Instructions 02 2014 A5E32317120 AB ...
Page 22: ...Overview 1 5 Status displays SIMATIC IPC547E 22 Operating Instructions 02 2014 A5E32317120 AB ...
Page 142: ...List of abbreviations SIMATIC IPC547E 142 Operating Instructions 02 2014 A5E32317120 AB ...
Page 154: ...Index SIMATIC IPC547E 154 Operating Instructions 02 2014 A5E32317120 AB ...