Technical specifications
8.4 Technical specifications
SIMATIC IPC547E
122
Operating Instructions, 02/2014, A5E32317120-AB
8.4.3
Power supply
Voltage
Maximum current
Voltage stability
+12 V
11 A
± 5%
+12 V
14 A
± 5%
–12 V
0.3 A
± 10%
+5 V
25 A
1
+ 5%, – 4%
+3.3 V
20 A
1
+ 5%, – 4%
+5 V
aux
2.5 A
+ 5%, – 3%
1
The total output of the +5 V and +3.3 V voltage must be ≤ 190 W.
The inrush current is:
●
≤ 80
A for 3.6 ms
Note
Operation on an uninterruptible power supply (UPS)
The power supply contains an active PFC (Power Factor Correction) circuit for adherence to
the EMC guidelines.
Uninterruptible power supplies must supply a sinusoidal output voltage in normal and
buffered mode when used with SIMATIC IPCs with an active PFC.
The characteristics of uninterruptible power supplies are described and classified in the
standards EN 50091-3 or IEC 62040-3. Devices with sinusoidal output voltage in normal and
buffered mode are identified with the classification "VFI-SS-...." or "VI-SS-....".
8.4.4
Redundant power supply
Voltage
Max. current
Voltage stability
+12 V
18 A
2
± 5%
+12 V
18 A
2
± 5%
+12 V
14 A
2
± 5%
–12 V
0.8 A
± 10%
+5 V
20 A
1
+ 5%, – 4%
+3.3 V
20 A
1
+ 5%, – 4%
+5 V aux
2.0 A
+ 5%, – 3%
1
The total output of the +5 V and +3.3 V voltage must be ≤ 100 W.
2
The total current of the +12 V voltage must be ≤ 25 A.
The inrush current of a plug-in module is:
●
≤ 210 A for 1.65
ms
Summary of Contents for SIMATIC IPC547E
Page 4: ...Preface SIMATIC IPC547E 4 Operating Instructions 02 2014 A5E32317120 AB ...
Page 22: ...Overview 1 5 Status displays SIMATIC IPC547E 22 Operating Instructions 02 2014 A5E32317120 AB ...
Page 142: ...List of abbreviations SIMATIC IPC547E 142 Operating Instructions 02 2014 A5E32317120 AB ...
Page 154: ...Index SIMATIC IPC547E 154 Operating Instructions 02 2014 A5E32317120 AB ...