![Siemens Simatic IPC520A Operating Instructions Manual Download Page 33](http://html.mh-extra.com/html/siemens/simatic-ipc520a/simatic-ipc520a_operating-instructions-manual_380795033.webp)
SIMATIC IPC520A
Operating Instructions, 11/2021, A5E51366325-AA
33
Installing OS and SDK components
4
4.1
Flashing the Ubuntu Operating System
Follow these steps to flash the Ubuntu Operating System:
Note
Operating System is not installed in new device.
1.
Install NVIDIA SDK Manager on a local PC. For detailed installation procedures, refer to the
NVIDIA website (
https://docs.nvidia.com/jetson/jetpack/install-jetpack/index.html
).
2.
Set the IPC520A to Force Recovery Mode (RCM).
–
2.1 Switch off the IPC520A.
–
2.2 Connect the IPC520A to local PC through the micro USB cable.
–
2.3 Keep pressing the Reset button.
–
2.4 Switch on the IPC520A and wait for more than 3 seconds, then release the Reset
button.
–
2.5 Check whether the IPC520A is entering the RCM: Enter the commend “
lsusb
”, then
the output returns should be like below:
Bus <xxx> Device <xxx>: ID 0955: <7e19> Nvidia Corp
Otherwise, redo the step 2.
3.
Start up NVIDIA SDK Manager, and register an NVIDIA account to log in to NVIDIA SDK
Manager.