Device maintenance and repair
7.3 Removing and installing hardware
SIMATIC IPC347G
56
Operating Instructions, 10/2020, A5E50059993-AA
7.3
Removing and installing hardware
7.3.1
Replacing the filter
Requirement
•
The device is fully disconnected from the line voltage, see "Switching off the device
(Page 40)".
•
The fan cover has been removed; see "Replacing the device fan (Page 57)".
•
An original spare part, for example, a filter pad with the same type.
Procedure - Removing the filter
1.
Unlock the front cover with the key
①
.
2.
Pull the handle in the direction of the arrow
②
to open the left-front door.
3.
Unscrew the marked screws.
4.
Pull the marked screw to open the fan bracket.
5.
Remove the filter in the direction of the arrow.
Procedure - Installing the filter
To install the filter, follow the steps for removing it in reverse order.