Installing and connecting the device
3.2 Mounting the device
SIMATIC IPC327E
22
Operating Instructions, 06/2019, A5E40965257-AD
NOTICE
Incorrect fixing elements
If you use anchors and screws other than those specified below for wall and vertical
mounting, safe mounting is not guaranteed. The device can fall and may be damaged.
Use only the anchors and screws specified in the following table.
Material
Bore diameter
Fixing element
Concrete
Select according to the
specification of the
mounting elements used
•
Anchor, ∅ 6
mm, 40 mm long
•
Screw, ∅ 4
-5 mm, 40 mm long
Plasterboard,
min. 13 mm thick
Toggle plug, ∅ 12 mm, 50 mm long
Metal,
min. 2 mm thick
•
Screw M4 × 15
•
M4 nut
3.2.2
Mounting on a standard rail
Mounting on a standard rail is suitable for horizontal mounting of the device.
Requirement
●
A SIEMENS 35 mm standard rail TH35-15 conforming to EN 60715:2001