Firmware/BIOS description SIMATIC IPC227G, IPC277G, IPC327G, IPC377G
Operating Instructions, 09/2021, A5E50059883-AB
11
Configure firmware
2
2.1
Starting the Setup Utility
You configure important firmware settings of your device using the firmware configuration
menu "Setup Utility".
Procedure
1.
Open the firmware selection menu (Page 9).
2.
Select the "Setup Utility" option on the "Main Page" with the arrow keys.
3.
Confirm your selection with the
<Enter>
button.
2.2
Keyboard inputs in Setup Utility
Button
Function
<F1>
Call help function.
<F5> or <F6>
Change firmware settings.
The <F5> key is used to take the previous setting possibility or value.
The <F6> key is used to take the next setting possibility or value.
<F9>
Load Optimal Defaults:
The firmware settings are reset to the safe default values.
The delivery state is restored.
NOTICE
:
All current firmware settings are overwritten.
<F10>
Exit Saving Changes:
All changes are saved. The device is restarted with the changed firmware
settings.
<Enter>
A submenu previously selected with the arrow keys opens. The value of a
firmware setting previously selected with the arrow keys can be changed.
[
←
] [
→
]
Navigate to a tab.
[
↑
] [
↓
]
Navigate to a submenu or a firmware setting. Confirm your selection with the
<Enter> button.
<Esc>
A submenu or tab or the Setup Utility is exited. If the Setup Utility is closed after
the confirmation prompt, changes to the firmware settings are discarded.