Installing and connecting the device
3.3 Connecting the device
SIMATIC IPC1047
Operating Instructions, 09/2018, A5E45118479-AA
37
Operation in the USA and Canada
For the United States and Canada, a CSA or UL-listed power cable must be used. The
connector must be compliant with NEMA 5-15.
240 V voltage
Use a flexible cable with UL approval and CSA mark as well as the following features: SJT
model with three conductors, min. 18 AWG conductor cross-section, max. length 4.5 m, and
tandem grounded connector 15 A, min. 250 V.
Requirement
●
The device is fully disconnected from the line voltage, see section
"Switching on the device (Page 40)".
●
1 power supply cable
Procedure
1. Set the on/off switch
①
to position '0'.
This prevents an automatic starting of the
device when plugging in the power supply
cable.
2. Plug the power cable plug
②
into the power
outlet.
3. Plug the power cable plug into the power
outlet.
4. Set the on/off switch
①
to position 'I'.
The power LED to the left of the on/off switch and on the front panel of the device lights
up.