Parameterizing the Mobile Panel
5.15 Functions for service and commissioning
Mobile Panels 2nd Generation
Operating Instructions, 09/2018, A5E33876626-AC
163
●
For controllers, the following applies:
–
The controller is of type S7-1200 or S7-1500.
–
HMI access is allowed in the settings.
–
The controller is in "STOP" state.
●
Your system administrator has provided you with the necessary information.
Procedure
The communication connection can only be configured for S7-1200 and S7-1500 controllers.
1.
Open the "Service & Commissioning" dialog using the "Service & Commissioning" icon.
2.
Change to the "IP Config" tab.
①
Button for changing IP address and device name
②
Button for changing the configured communication connections
3.
Open the "Set Connection" dialog using the "Set Connection" button.
①
Save setting
②
Selected communication connection
③
List of configured communication connections
④
Text box for the IP address