Assigning device parameters
5.3 Configuration settings of the device
Industrial Thin Client ITC1200, ITC1500, ITC1900, ITC2200
Operating Instructions, 04/2013, A5E03474888-02
49
Specify speed and mode of the connection
The device detects the data rate and the connection mode of its physical connection partner
and adapts itself automatically. The "Set automatically" option is therefore selected by
default. The other parts of the dialog are disabled. A switch can also be a connection partner.
You can, however, set the data rate and the connection mode manually.
Note
Disable the automatic setting only if the connection partner requires this.
If the "Set automatically" option is not selected, the following default settings apply:
●
"Rate": 100 Mbps
●
"Half duplex"
Basic rule for specifying speed and mode: The connection works best if you specify one of
the following combinations:
●
Automatic detection for both connection partners or
●
Same speed and same mode for both connection partners
See also
Calibrating the touch screen (Page 98)
Remote configuration of several devices (Page 66)
Opening the configuration (Page 35)
PROFINET basic functions (Page 57)