Assigning device parameters
5.3 Configuration settings of the device
Industrial Thin Client ITC1200, ITC1500, ITC1900, ITC2200
Operating Instructions, 04/2013, A5E03474888-02
39
●
Desktop settings under "Desktop":
–
Taskbar
–
On-screen keyboard
–
Background image
●
Application settings under "Applications": Web browser settings
Note
Forced termination of connection
When you change and save the configuration settings, all open client-server connections
are terminated and all open programs are closed without a confirmation prompt. The
autostart connections are re-established afterwards and the new configuration settings
are put into effect.
Access without logon
If you open the configuration settings and do not log on as administrator, only "Configuration
> Information" is shown in the Start menu with the current network settings and device
information.
You have read-only access to the device and network data and cannot make any changes.
Access with logon
In order to view and edit the configuration settings (read and write access), you must log on
with a valid administrator password.
Note
Permanent data
Some data cannot be configured, for example, "MLFB number", "Firmware version", "MAC
address", etc.
Symbols
Use the symbols above to manipulate the configuration settings.
You can
●
①
"Log on" as an administrator and "Log off" again
●
②
"Restart" the device.
●
③
"Save" the configuration settings
●
④
Open "Help".
●
⑤
"Exit" the configuration.