FM 453 Servo Drive / Step Drive Positioning Module
C79000-G7076-C453-01
4.5
Connecting the Encoders
Please note:
Note
Use only shielded cables. The shielding must be connected to the metallic or
metallized connector jacket.
The cable sets supplied as an accessory offer excellent immunity from inter-
ference, as well as cross-sections large enough for the power supply to the
encoders.
When cables are routed unprotected, the cable shielding must be connected
to a grounded shielding bus over a large contact area in the proximity of the
FM 453 and the sensors.
e.g. absolute
encoder
(SSI)
e.g.
ROD 320
(built-in en-
coder in 1FT5)
e.g.
linear scale
with EXE
FM 453
Connecting
cable
X3
X3
X3
X3
e.g. incremen-
tal encoder
with RS 422
Channels 1
to 3
Fig. 4-10
Connecting Sensors
To Connect the
Connecting Cables
Wiring the FM 453