Description of Functions
9-19
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
9.2.3
Reference point approach
Overview
In Reference-point approach mode, the direction keys (R+ or R
−
) or Start are used
to position the axis to a point (reference-point coordinate MD16) specified in the
machine data.
The axis is thus synchronized (see Section 9.6.1).
The override is set at 100% for the reducing speed.
An active zero offset or Set actual value is reset.
Machine data
The following table lists the machine data that is of significance for reference-point
approach:
MD
Designa-
tion
Value/Meaning
Comments/
Unit
16
Reference-
point coor-
dinate
−
1,000,000,000
−
+1,000,000,000
[MSR]
18
Type of ref-
erence-
point ap-
proach
0 = dir, current-sourcing pattern zero/
zero pulse external, to right of reference point switch
1 = dir, current-sourcing pattern zero/
zero pulse external, to left of reference point switch
2 = direction
−
, current-sourcing pattern zero/
zero pulse external, to right of reference point switch
3 = direction
−
, current-sourcing pattern zero/
zero pulse external, to left of reference point switch
4 = dir, reference point switch center
5 = direction
−
, reference point switch center
8 = direction + , reference point switch edge
9 = direction
−
, reference point switch edge
27
Reference-
point shift
−
1,000,000,000
−
+1,000,000,000
[MSR]
28
Referencing
speed
10
−
v
max
(MD23)
[MSR/min]
29
Reducing
speed
10
−
x (see Machine data list, Table 5-4)
[MSR/min]
34
Inputs
5 = reference point switch for
reference point approach
6 = reversing switch for reference point approach
Assigned
depending
on input
MSR stands for measurement system raster (see Section 5.3.1)
Handling by the user
S
with connected reference-point switch (RPS).
S
without connected reference-point switch (RPS).
Summary of Contents for SIMATIC FM 353
Page 22: ...Product Overview 1 12 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 32: ...Installing and Removing 3 6 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 282: ...Description of Functions 9 82 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 354: ...User Data Block AW DB B 16 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...