6-1
SIMATIC Field PG P4 Manual
A5E00180080-04
Error Diagnostics
What Does This Chapter Contain?
This chapter will help you to locate, identify, and in some cases eliminate simple
errors and faults.
Error/Fault
Remedy
Device LED does not light up
•
PG is switched off
•
Power supply not properly connected
•
Battery run down or not installed
•
Press the Power Button
•
Check the power supply, power cable, and power
plug
•
Charge or install the battery
External monitor remains dark
•
LCD enabled is entered in SETUP
•
Enter CRT enabled or SIMULTANEOUS in SETUP
Message on the Display :”Invalid configuration information... Press the F1 key for continue, F2 to
run Setup utility”
•
Configuration data not correct
•
Hit the “F2” key, check the configuration data in the
SETUP program, if necessary adapt the default
values, check the error messages in the first
SETUP menu
Message on the Display ”No boot device available” NTLDR not found, check boot data carrier
•
No bootable disk in drive A:
•
Wrong hard disk type entered in SETUP
•
Replace the disk with a boot disk
•
Use the “Autodetect Fixed Disk” function
Message on the Display : ”Keyboard stuck key failure”
•
A key became blocked during the self-test of
the keyboard
•
Check the keyboard. Restart the system if need be.
Every time a key is pressed, a beep is heard and no characters are displayed
•
Keyboard buffer overflow
•
<CTRL> <PAUSE>
< \ > key does not exist
•
Wrong keyboard driver
•
German keyboard: <ALTGr> <ß>
•
International keyboard : <\> key
6
Summary of Contents for SIMATIC Field PG P4
Page 8: ...Preface viii SIMATIC Field PG P4 Manual A5E00180080 04 ...
Page 12: ...Contents xii SIMATIC Field PG P4 Manual A5E00180080 04 ...
Page 18: ...Important Notes 1 6 SIMATIC Field PG P4 Manual A5E00180080 04 ...
Page 92: ...Error Diagnostics 6 2 SIMATIC Field PG P4 Manual A5E00180080 04 ...
Page 126: ...Technical Specifications B 6 SIMATIC Field PG P4 Manual A5E00180080 04 ...