Installation
Distributed I/O Device ET 200R
(4)J31069-D0427-U001-A2-7618
3–1
Installation
Caution
To avoid damaging module electronics, all voltages for the ET 200R must be
turned off (i.e., de-energized) before the modules can be installed or removed.
Mounting dimensions
Dimensions of the ET 200R: 54 mm x 150 mm x 55 mm (W x L x H). Including the
X01/X02 screw connections, height is 64 mm.
Settings to be made
The PROFIBUS address is set with 2 rotary switches on the ET 200R module.
When the ET 200R distributed I/O device is the first or the last DP slave in a
PROFIBUS-DP network with copper conductors (RS 485 bus configuration), the
bus does not need to be equipped with a terminal resistor since this is integrated in
the module.
How to install
Depending on which model of the device you have the module is mounted on the
robot arm or on the tool.
You will need the following to mount the module on the Kempf box:
•
1 pan head screw (DIN 6912-M4x60)
•
2 pan head screws (DIN 6912-M4x54)
If you mount the module in a different place, use screws of the same type. You
must then select the length to meet the requirements.
Mounting position
The ET 200R can be mounted in any position.