Installation
4.9 Mounting a fail-safe frequency converter
ET 200pro FC
Operating Instructions, 07/2016, A5E01100763B AC
59
4.9
Mounting a fail-safe frequency converter
Fail-safe applications are configured basically the same as standard applications but with the
following differences:
●
Mounted to the left of the frequency converter must be a module through which the safety
functions of the frequency converter can be actuated, for example:
–
an F-RSM repair switch module
–
an F-Switch
●
Only the following modules are allowed to be connected between the F-RSM or F-Switch
and the fail-safe frequency converter:
–
400 V shutdown module
–
all direct or reversing starters
–
the standard frequency converter
–
the fail-safe frequency converter
Procedure:
Mount one after the other:
1.
Rack
2.
Interface module
3.
Bus module for F-RSM or F-Switch
4.
Bus module for frequency converter
5.
Terminating module
6.
Connection module for the interface module
7.
F-RSM or F-Switch
8.
Frequency converter