Commissioning and Diagnostics
ET 200iS Distributed I/O Station
7-2
A5E00087831-02
Defining a Configuration
Configuration involves configuring and setting parameters for the ET 200iS with a
programming device (PG).
Configuration
When you configure your project, you set the basic characteristics of the DP slaves
(for example, network parameters, module selection in HW Config).
You configure the ET 200iS with
•
STEP
7
•
COM PROFIBUS or with suitable configuration software (using the GSD file).
Parameter Assignment
When you make the parameter assignments, you set the parameters of the ET
200iS and the HART field devices.
•
With STEP 7, you make the parameter settings for the ET 200iS in HW Config.
SIMATIC PDM is integrated as an optional package in STEP 7.
•
Outside STEP 7, you set the parameters for the ET 200iS and the HART field
devices with SIMATIC PDM. SIMATIC PDM installed as a standalone version.
Cyclic Data Transfer Via PROFIBUS DP
Data is exchanged between the CPU (for example, S7-400) and the ET 200iS. The
following data is transferred:
•
the cyclic user data of the inputs and outputs including the value status of the
inputs
On the CPU, this data is prepared by the PCS 7 drivers and CFC (Continuous
Function Chart) for plant visualization. This data is then presented on the OS by
means of WINCC.
For plant visualization, this data can be prepared by the PCS 7 drivers and CFC
(Continuous Function Chart) on the CPU and then displayed on the OS with
WINCC.
The parameters (for network configuration, for example) are also transferred
cyclically.
Acyclic Data Transfer Via PROFIBUS DP
Acyclic data exchange takes place between the ET 200iS and the PG / PC
(SIMATIC PDM). The ET 200iS receives its parameters using acyclic data
exchange. Identification data is also transferred and displayed in SIMATIC PDM.
•
Diagnostics
and
interrupts
•
Data records (S7 only)
Summary of Contents for SIMATIC ET 200iS
Page 20: ...Preface ET 200iS Distributed I O Station 1 6 A5E00087831 02 ...
Page 34: ...Product Overview ET 200iS Distributed I O Station 2 14 A5E00087831 02 ...
Page 84: ...Installation ET 200iS Distributed I O Station 5 18 A5E00087831 02 ...
Page 168: ...Maintenance ET 200iS Distributed I O Station 8 6 A5E00087831 02 ...
Page 184: ...Terminal Modules ET 200iS Distributed I O Station 10 8 A5E00087831 02 ...
Page 188: ...Power Supply Module ET 200iS Distributed I O Station 11 4 A5E00087831 02 ...
Page 320: ...Dimension Drawings ET 200iS Distributed I O Station 17 4 A5E00087831 02 ...
Page 330: ......
Page 332: ...Certifications ET 200iS Distributed I O Station 20 2 A5E00087831 02 ...
Page 333: ...Certifications ET 200iS Distributed I O Station A5E00087831 02 20 3 ...
Page 334: ...Certifications ET 200iS Distributed I O Station 20 4 A5E00087831 02 ...
Page 336: ...Certifications ET 200iS Distributed I O Station 20 6 A5E00087831 02 ...
Page 337: ...Certifications ET 200iS Distributed I O Station A5E00087831 02 20 7 20 1 3 Power supply PS ...
Page 338: ...Certifications ET 200iS Distributed I O Station 20 8 A5E00087831 02 ...
Page 339: ...Certifications ET 200iS Distributed I O Station A5E00087831 02 20 9 20 1 4 4DI NAMUR ...
Page 340: ...Certifications ET 200iS Distributed I O Station 20 10 A5E00087831 02 ...
Page 341: ...Certifications ET 200iS Distributed I O Station A5E00087831 02 20 11 ...
Page 342: ...Certifications ET 200iS Distributed I O Station 20 12 A5E00087831 02 20 1 5 2DO DC25V 25mA ...
Page 343: ...Certifications ET 200iS Distributed I O Station A5E00087831 02 20 13 ...
Page 347: ...Certifications ET 200iS Distributed I O Station A5E00087831 02 20 17 ...
Page 348: ...Certifications ET 200iS Distributed I O Station 20 18 A5E00087831 02 20 1 8 2AI RTD ...
Page 349: ...Certifications ET 200iS Distributed I O Station A5E00087831 02 20 19 ...
Page 350: ...Certifications ET 200iS Distributed I O Station 20 20 A5E00087831 02 20 1 9 2AI TC ...
Page 351: ...Certifications ET 200iS Distributed I O Station A5E00087831 02 20 21 ...
Page 352: ...Certifications ET 200iS Distributed I O Station 20 22 A5E00087831 02 20 1 10 2AO I 2AO I HART ...
Page 353: ...Certifications ET 200iS Distributed I O Station A5E00087831 02 20 23 ...
Page 366: ...Marking ET 200iS Distributed I O Station 21 8 A5E00087831 02 ...
Page 416: ...26 Product Information RS 485 IS Coupler 6ES7 972 0AC80 0XA0 A5E00207628 01 ...
Page 417: ...27 Product Information RS 485 IS Coupler 6ES7 972 0AC80 0XA0 A5E00207628 01 ...
Page 418: ...28 Product Information RS 485 IS Coupler 6ES7 972 0AC80 0XA0 A5E00207628 01 ...
Page 419: ...28 Produktinformation RS 485 IS Koppler 6ES7 972 0AC80 0XA0 A5E00207082 01 ...
Page 420: ...28 Product Information RS 485 IS Coupler 6ES7 972 0AC80 0XA0 A5E00207628 02 ...