SIMATIC Rack PC 647B
Getting Started, 12/2008, A5E02147333-01
19
Installation
4
4.1
Installing the device
Optional installation locations
The device can be installed horizontally in control desks, in switch cabinets and in 19-inch
rack systems.
Optional mounting methods
Options of mounting the device
●
Mounting on cabinet brackets
●
Mounting on device bases
●
Mounting on telescopic rails
When telescopic rails are used for mounting, the device can be withdrawn fully from the
cabinet or rack.
For more detailed information on telescopic rails, refer to the sections Technical data of
the telescopic rails (Page 20) and Dimensional drawing for the use of telescopic rails
Figure 4-1
Position of the mounting holes ①
CAUTION
The mounting screws of the telescopic rails may not protrude more than 5 mm into the
enclosure.
CAUTION
Risk of injury!
It is not permitted to install the device only on the 19-inch brackets of the front panel.