Controller
6.10 Technical specifications
ATE500E
86
System Manual, 09/2017, A5E33917696-AD
6.10
Technical specifications
Article number
6FB1211-5AT10-7AT2
6FB1211-1AT10-7AT3
General information
Product brand name
SIDOOR
Product version
With relay outputs
with CAN interface
Optional product expansion
SIDOOR TRANSFORMER (6FB1112-0AT20-2TR0),
SIDOOR TRANSFORMER UL (6FB1112-0AT21-2TR0),
SIDOOR NT40 (6FB1112-0AT20-3PS0)
Manufacturer's article no. of the usable
motor
6FB1203-0AT12-7DA0
Mean time between failures (MTBF)
19 y
Installation type/mounting
Installation and mounting instructions
No direct sunlight, requirements specific to the end ap-
plication must be observed. NFPA industry environment:
Installation outside a control cabinet only horizontal.
NFPA elevator environment: Must be installed in a fire
protection enclosure
Supply voltage
Design of the power supply
via SIDOOR mains transformer / NT40 or via DC
Rated value (DC)
36 V; with MED280: At 24 V DC max. door speed of 500
mm/s; at 28.8 V DC max. door speed of 800 mm/s
permissible range, lower limit (DC)
19.2 V
permissible range, upper limit (DC)
38 V
Protection in case of DC supply
Use of a circuit breaker in the supply path according to
60898-1, 8A, C-characteristic type SIEMENS: 5SY4108-
7 or 5SY4108-7KK11
Input current
I²t, min.
30 A²·s
Encoder supply
Output voltage (DC)
24 V
short-circuit proof
Yes
Overload-proof
Yes
Remark
Ensure correct polarity! CAUTION: Do not supply with
external voltage!
Output current
•
For output (24 V DC), max.
400 mA
Power
Active power input
85 W
Active power input, max.
540 W
Active power input (standby mode)
5 W
6 W