ATD4xxW Door Controller for Industrial Applications
System Manual, 01/2017, A5E38080677-AB
259
Connecting and commissioning
9
9.1
Overview of safety and commissioning
WARNING
Dangerous electrical voltage!
When electrical devices are used, certain parts of them have to carry dangerous voltages.
Failure to observe the operating instructions can therefore lead to serious injuries or
material damage.
Observe the operating instructions.
WARNING
Risk of injury during commissioning
•
The door movements cannot always be externally controlled while the controller is being
commissioned (in particular during the automatic determination of parameters). The light
barrier is not active during the learn run.
•
During the learn run, the force is > 75 N and the energy > 4 J.
An authorized person must therefore be posted near the door to ensure that no one else
can enter the vicinity of the door during commissioning.
Note
The motor temperature must not be below 0°C during the learn run, as otherwise the mass
to be moved will be incorrectly determined, and the opening and closing speed may lie in an
impermissible range.
Summary of Contents for SIDOOR ATD401W
Page 1: ......