Appendix
A.1 Profiles and adjustment ranges
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
System Manual, 06/2016, A2B00096162-AN
325
A.1.10.2
Adjustment ranges SIDOOR MEG250
Table A- 26 Adjustment ranges SIDOOR MEG250 L / R
Parameter
Unit
Adjustment range
ATE250S
Creep distance OPEN
mm
0 … 100
Cutter distance OPEN
mm
0 … 100
Creep distance CLOSE
mm
0 … 100
Cutter distance CLOSE
mm
0 … 100
Maximum speed OPEN
mm/s
100 … 750
Creep speed OPEN
mm/s
30 … 90
Cutter speed OPEN
mm/s
30 … 90
Initial speed OPEN
mm/s
30 … 90
Maximum speed CLOSE
mm/s
100 … 500
Creep speed CLOSE
mm/s
30 … 90
Cutter speed CLOSE
mm/s
30 … 90
Initial speed CLOSE
mm/s
30 … 90
Nudge speed CLOSE
mm/s
50 … 250
Acceleration ramp OPEN
mm/s
2
300 … 1400
Braking ramp OPEN
mm/s
2
300 … 1000
Reversing ramp OPEN/CLOSE
mm/s
2
300 … 1000
Acceleration ramp CLOSE
mm/s
2
300 … 1400
Braking ramp CLOSE
mm/s
2
300 … 1000
Reversing ramp CLOSE/OPEN
mm/s
2
300 … 1000
Continuous torque (power) OPEN
A
0 … 3.3
Continuous torque (power) CLOSE
A
0 … 3.3
Cutter press-on torque
A
0 … 12.8
Static opening force
N
70 … 300
Static closing force
N
70 … 230
Static cutter force CLOSE
N
70 … 230
Static nudge force CLOSE
N
70 … 230
The parameter is accepted with the door stationary at the end stop "CLOSED" or end stop
"OPEN".