Controllers
6.11 Structure of user data/process data
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
System Manual, 06/2016, A2B00096162-AN
213
ASDRV signal
The ASDRV signal is located in the high byte of TZW2 (bit 8). It has a binary structure.
Table 6- 89 ASDRV signal
ASDRV signal
value
Name
Description
0
AssistedDrive ac-
tive
An external assisting force within the parameterized thresh-
old values has been found
1
AssistedDrive inac-
tive
An external assisting force within the parameterized thresh-
old values has not been found
You will find further information about the ASDRV signal and the corresponding drive
function in Section AssistedDrive (Page 69).
ASStp signal
The ASStp signal is located in the high byte of TZW2 (bit 9). It has a binary structure.
Table 6- 90 ASStp signal
ASStp signal
value
Name
Description
0
ImpulseStop inac-
tive
An external opposing force within the parameterized limit
values was not found
1
ImpulseStop active An external opposing force within the parameterized limit
values was found
You will find further information about the ASStp signal and the corresponding drive function
in the Section ImpulseStop (Page 67).
6.11.2.9
TZW3 - Technology status word 3
Table 6- 91 Technology status word 3 (TZW3)
TZW3
15 … 5
4
3
2
1
0
Reserved
D-IN
Table 6- 92 D-IN
Group
Bit
Description
Note
D-IN
0
Input 0
X6, INPUT 1
1
Input 1
X6, INPUT 2
2
Input 2
X6, INPUT 3
3
Input 3
X6, INPUT 4
4
Input 4
X5, INPUT 0
5 … 15
Reserved