Siemens SENTRON SUPERSWITCH 3KL83 Series Operating Instructions Manual Download Page 1

2.5 mm

13 mm
16 mm

0.5 x 3 mm

PZ 5

Contents

Required tools

Assembly

1  mm

3

L1V30606645003-01 | 01

3KL83...-.. (200A-400A)
3KA83...-.. (200A-400A)

IEC 60947-1
IEC 60947-3

Hazardous voltage will cause death or serious injury.

 Turn off and

lock out all power supplying this device before working on this device.
Replace all covers before power supplying this device is turned on.

Installation & Maintenace must be carried out by qualified personnel.

NOTICE

DANGER

EN

!

2P: 2x
3P: 3x
4P: 4x

1x

1x

2P: 4x
3P: 6x
4P: 8x

3K.83..M10X30

3K.83..-5

M10X30

Permissible mounting position

Drilling Plan for mounting plate

2P/3P/4P : M8 x 20 (4x)
Torque 10....14 Nm
(Not in scope of supply)

M8 (4x)

15

A

Center of
Shaft

For 3KL8

SENTRON SUPERSWITCH

Switch Disconnector Fuse - Size 3

Mounting Details:

Summary of Contents for SENTRON SUPERSWITCH 3KL83 Series

Page 1: ...orking on this device Replace all covers before power supplying this device is turned on Installation Maintenace must be carried out by qualified personnel NOTICE DANGER EN 2P 2x 3P 3x 4P 4x 1x 1x 2P 4x 3P 6x 4P 8x 3K 83 M10X30 3K 83 5 M10X30 Permissible mounting position Drilling Plan for mounting plate 2P 3P 4P M8 x 20 4x Torque 10 14 Nm Not in scope of supply M8 4x 15 A Center of Shaft For 3KL8 ...

Page 2: ...mm L1V30606645003 01 02 Provision for Fuse monitoring 2 2 3KL831 3KA831 3KL8322 3KA822 Max Lug Size 2X120 mm M10 x 30 Torque 20 Nm to 28 Nm 3KL83 5 3KA83 5_Netrual Link Max Lug Size 120 mm M10 x 30 Torque 10 Nm to 28 Nm Installation of Shaft ...

Page 3: ...n position 1 2 are essential 3P Phase Barrier in position 1 2 3 are essential 4P Phase Barrier in position 1 2 3 4 are essential PZ5 x 13 5 2 1 2 4Nm Coupler 7 1 45 5 1 8UC Coupler depth adjustment Use Depth Setting Templet 8UC6046 2 8UC 3K Panel Door 1 5 4Thk 285 310 Phase Barrier 3KX83430AE Mounting Details for Front Drive 8UC6314 1BB00 ...

Page 4: ... 5 x 3 mm 0 5 x 3 mm Assembly L1V30606645003 01 04 2P 3KX83410AF 3P 3KX83410AE 4P 3KX83410AG 2P 3KX83460AF 3P 3KX83460AE 4P 3KX83460AG Terminal cover Rear cover Rear Phase Barrier Kit 2P 3P 4P 3KX83469AE ...

Page 5: ...KX83400AE 4P 3KX83400AG 2P 3P 4P Replace phase barrier in position 1 with Fuse Cover Phase Barrier 2P Add Fuse Cover Phase Barrier in position 3 3P Add Fuse Cover Phase Barrier in position 4 4P Add Fuse Cover Phase Barrier in position 5 3KX35521YC 3KX35521YD Fuse Cover Phase Barrier Kit 3KX83409AE Fuse Cover Mounting Aux Switch ...

Page 6: ...NG LEVER AUXLIARY SWITCH NEUTRAL LINK OFF POSITION INDICATOR 3 THICK 310 13 2 25 32 5 A 287 313 222 95 55 2 70 70 M10 M10 65 C D 240 380 Dimension Details for SDF in Enclosure Overall Dimensional details 3KL8 3KA8 3P 3KL8 3P N 3KL8 3KA8 2P 3KL8 3KA8 4P For missing Dimension refer 3P 3P N For missing Dimension refer 3P 3P N ...

Reviews: