Configuration
4.5 WinCC flexible
Fail-safe operation of the Mobile Panel 277F IWLAN
72
Function Manual, 08/2008, 6AV6691-1FQ01-2AB0
4.5
WinCC flexible
4.5.1
Configuration overview
For fail-safe operation of the HMI you must configure the following areas of WinCC flexible
ES:
● Settings of the HMI device:
Set the PROFIsafe address of the HMI device in the project view under "Device settings"
> "Device settings".
● Effective ranges editor
Configure the effective ranges defined when the plant was planned in the project view
under "Device settings" > "Effective ranges".
● Figures
● Configure the following in the project view under "Images":
– Display of the project ID
You must assign a unique project ID for each project.
The project ID is used to check which project is currently on the HMI.
You must update the project ID each time the project is changed, e.g. by listing a
version or date.
Configure the display of the project ID at a point of the project that can be displayed at
any time in the current project, e.g. start screen or in a service display.
– Objects that are specially designed for fail-safe operation of the HMI device
Additional information on configuration with WinCC flexible
Only a brief overview is provided below. A detailed description of the configuration is
provided in the WinCC flexible Information System.