background image

 

 

SCALANCE XR-300M PoE 

 

___________________ 
___________________ 
___________________ 
___________________ 
___________________ 
___________________ 
___________________ 
___________________ 
___________________ 

 

SIMATIC NET 

Industrial Ethernet switches 

SCALANCE XR-300M PoE 

Compact Operating Instructions 

 

  

05/2016 

A5E02661178-10 

Introduction 

 

 

Safety instructions 

 

 

Description 

 

 

Installation 

 

 

Connecting up 

 

 

Technical specifications 

 

 

Dimension drawings 

 

 

Approvals 

 

 

Appendix 

 

Summary of Contents for SCALANCE XR324-4M PoE

Page 1: ...______ ___________________ ___________________ ___________________ SIMATIC NET Industrial Ethernet switches SCALANCE XR 300M PoE Compact Operating Instructions 05 2016 A5E02661178 10 Introduction 1 Safety instructions 2 Description 3 Installation 4 Connecting up 5 Technical specifications 6 Dimension drawings 7 Approvals 8 Appendix A ...

Page 2: ...perated only by personnel qualified for the specific task in accordance with the relevant documentation in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Si...

Page 3: ...ver Ethernet PoE 16 3 4 Product characteristics 17 3 5 The SET SELECT button 18 3 6 LED display 19 3 7 C PLUG 23 3 7 1 Area of application and function of the C PLUG 23 3 7 2 Removal and insertion of the C PLUG rack devices 24 4 Installation 27 4 1 Safety notices for installation 27 4 2 Suitable cables for temperatures above 70 C cable 50 C 70 C ATEX 28 4 3 Suitable cables for temperatures in exce...

Page 4: ... power supply 51 5 5 3 1 100 to 240 VAC XR 300M PoE product group 51 5 5 3 2 Notes on the power supply 100 to 240 VAC 51 5 5 3 3 Fitting the connector for 100 to 240 V AC 52 5 5 3 4 Connecting the 100 to 240 V AC power supply 53 6 Technical specifications 55 6 1 Construction installation and environmental conditions 55 6 2 Connectors and electrical data 57 6 3 Cable lengths 59 6 4 Other properties...

Page 5: ...ructions compact Classification Description Terms used Product line For all devices and variants of all product groups within the SCALANCE X 300 product line the term IE switches X 300 is used IE switches X 300 Product group For all devices and variants of a product group only the product group is used XR 300M PoE Device For a device only the device name is used XR 324 4M PoE Variant For a variant...

Page 6: ... register for a product specific newsletter For the safe operation of a plant machine however it is also necessary to integrate the automation components into an overall IT security concept for the entire plant machine which corresponds to the state of the art IT technology You will find information on this in http www siemens com industrialsecurity Products from other manufacturers that are being...

Page 7: ...a cable outlet on front Diagnostics port at rear 6GK5 324 4QG00 3AR2 1 x 24 VDC PoE LEDs and diagnostics port at rear connector power supply and data cable outlet at rear 6GK5 324 4QG00 1HR2 1 x 100 to 240 VAC PoE LEDs and diagnostics port on front connector power supply and data cable outlet at rear 6GK5 324 4QG00 3HR2 XR324 4M PoE TS 1 x 24 VDC PoE module varnished LEDs connector power supply an...

Page 8: ...SC port 100 Mbps multimode FO cable up to max 5 km LD FE SC port 100 Mbps single mode FO cable up to max 26 km SC port 1000 Mbps multimode FO cable up to max 750 m LD SC port 1000 Mbps single mode FO cable up to max 10 km LH SC port 1000 Mbps single mode FO cable up to max 40 km LH SC port 1000 Mbps single mode FO cable up to max 70 km If information applies to all devices the term IE Switches X 3...

Page 9: ...l safety notices relating to protection against explosion WARNING EXPLOSION HAZARD DO NOT OPEN WHEN ENERGIZED This equipment is suitable for use in Class I Division 2 Groups A B C and D or non hazardous locations only This equipment is suitable for use in Class I Zone 2 Group IIC or non hazardous locations only 2 1 Important notes on using the product group XR 300M PoE Safety notices on the use of...

Page 10: ...arate power supplies both must meet these requirements A power source that supplies safety extra low voltage combined with a following NEC Class 2 power limiter also meets the requirements according to IEC 60950 1 EN 60950 1 VDE 0805 1 or NEC Class 2 A suitable power limiter is for example the redundancy module SITOP PSE202U NEC Class 2 article number 6EP1962 2BA00 The maximum current via the 24 V...

Page 11: ...alled in a cabinet or a suitable enclosure Notices for use in hazardous areas according to ATEX WARNING Requirements for the cabinet enclosure To comply with EU Directive 94 9 ATEX95 this enclosure must meet the requirements of at least IP54 in compliance with EN 60529 WARNING Suitable cables for temperatures in excess of 70 C If the cable or conduit entry point exceeds 70 C or the branching point...

Page 12: ... does not exceed the voltage limits 25 VAC or 60 VDC 2 3 Important notes on using the device in hazardous areas WARNING WARNING EXPLOSION HAZARD DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLESS AREA IS KNOWN TO BE NON HAZARDOUS WARNING Restricted area of application This equipment is suitable for use in Class I Division 2 Groups A B C and D or non hazardous locations only WARNING Restricted area of ...

Page 13: ...are not approved for use in hazardous areas according to EC RL 94 9 ATEX or IECEx NOTICE Securing cables with dangerous voltage Make sure that the connector cannot be released accidentally by pulling on the connecting cable Lay the cables in cable ducts or cable channels and secure the cables where necessary with cable ties 2 5 Safety requirements Installation 100 to 240 VAC Safety requirements fo...

Page 14: ...Safety instructions 2 5 Safety requirements Installation 100 to 240 VAC SCALANCE XR 300M PoE 14 Compact Operating Instructions 05 2016 A5E02661178 10 ...

Page 15: ...rsons Loss of the approvals Violation of the EMC regulations Use only undamaged parts 1 Make sure that the package is complete 2 Check all the parts for transport damage 3 2 Components of the product XR 300M PoE Components that ship with the SCALANCE XR324 4M PoE and XR324 4M PoE TS switches The following components ship with a SCALANCE XR324 4M PoE or XR324 4M PoE TS Device with C PLUG exchangeab...

Page 16: ... the Ethernet cable Requirements for the Ethernet cable For 10Base T 100Base TX a 4 wire cable is adequate for data transmission and power supply With 1000BASE T an 8 wire cable is necessary for data transmission Alternative B Power is transferred on the free wires 4 5 7 and 8 of the Ethernet cable Requirements for the Ethernet cable For 10Base T 100Base TX 1000BASE T an 8 wire cable is needed PoE...

Page 17: ...companying CD 3 4 Product characteristics Connection options of the SCALANCE XR324 4M PoE and XR324 4M PoE TS switches The switches are partly modular devices and all have 24 ports 16 fixed ports on the base device Ports P1 to P8 8 PoE compliant gigabit ports RJ 45 jacks with securing collars for connection of end devices or other network segments Non PoE compliant end devices can also be connecte...

Page 18: ...ll other devices this button is on the front panel of the housing beside the LED display The SET SELECT button has several functions that are described below Change the display mode By pressing the button briefly you change to the display mode of the LED display For more detailed information on this topic refer to the section LED display Resetting the device to the factory defaults If you reset al...

Page 19: ...e is active you will need to press the SET SELECT briefly possibly several times until display mode B is active 2 Hold down the SET SELECT button for five seconds After three seconds the DM LED begins to flash If you release the button before the five seconds have elapsed the action is aborted 3 The result of the action depends on the initial situation If the redundancy manager and media redundanc...

Page 20: ...ccurred red flashes Bad firmware image During normal operation the F LED provides the following information LED color LED status Meaning during operation off No operating problems red on The device has detected an error The signaling contact opens The DM LED for the display mode The DM LED Display Mode indicates which of the four display modes A B C or D is currently active The meaning of the L1 L...

Page 21: ...higher than 17 V redundant supply The following applies to the X 300EEC For devices with power supply unit 24 to 48 VDC Limit voltage 17 VDC For devices with a multiple range power supply unit 100 to 240 VAC 60 to 250 VDC Limit voltage 46 5 VDC or 80 VAC Meaning in display mode D LED Color Status Meaning L1 L2 _ off Power supply L1 L2 is not monitored If L1 L2 falls below 17 V the signaling contac...

Page 22: ...ists and port in normal status In this status the port can receive and send data flashes once per second Link exists and port in blocking status In this status the port only sends and receives management data no user data flashes 3 times per sec ond Link exists and port turned off by management In this status no data is sent or received via the port flashes 4 times per sec ond Port exists and is i...

Page 23: ...was established at the port for example no cable insert ed this triggers the signaling contact and an error state results 3 7 C PLUG 3 7 1 Area of application and function of the C PLUG Area of application The C PLUG configuration plug that ships with the product is an exchangeable memory medium for storing the configuration data of the device The device can also be operated without a C PLUG This ...

Page 24: ...mode is active when a C PLUG is inserted With written C PLUG A device with an accepted C PLUG inserted uses the configuration data of the C PLUG automatically when it starts up Acceptance is possible only when the data was written by a compatible device type Response to errors Inserting a C PLUG that does not contain the configuration of a compatible device type accidentally removing the C PLUG or...

Page 25: ... of the C PLUG posi tion A and the slot and release the C PLUG 4 Remove the C PLUG and screw the cover plate firmly in place again Inserting the C PLUG 1 Turn off the power to the device 2 Remove the cover plate on the right hand side of the device 3 The housing of the C PLUG has a protruding ridge on the long side position B The slot has a groove at this position Insert the C PLUG correctly orien...

Page 26: ...Description 3 7 C PLUG SCALANCE XR 300M PoE 26 Compact Operating Instructions 05 2016 A5E02661178 10 ...

Page 27: ...notices on use in hazardous areas General safety notices relating to protection against explosion WARNING EXPLOSION HAZARD The replacement of components may impair suitability for Class 1 Division 2 or zone 2 WARNING When used in hazardous environments corresponding to Class I Division 2 or Class I Zone 2 the device must be installed in a cabinet or a suitable enclosure Safety notices for use acco...

Page 28: ...duit entry point exceeds 70 C or the branching point of conductors exceeds 80 C special precautions must be taken If the equipment is operated in an air ambient in excess of 50 C only use cables with admitted maximum operating temperature of at least 80 C Further notes CAUTION Use only approved components If you use components and accessories that are not approved for SIMATIC NET devices or their ...

Page 29: ... of the reason for restricted access and the required safety measures at an ambient temperature higher than 50 C NOTICE Use only approved components If you use components and accessories that are not approved for SIMATIC NET devices or their target systems this may violate the requirements and regulations for safety and electromagnetic compatibility Use only components that are approved for SIMATI...

Page 30: ...xing the mounting brackets depending on the mounting position required 19 rack mounting 19 rack mounting is possible for all rack devices identified by XR Refer to the technical specifications Installation options table for each product group The rack device is installed using two mounting brackets fitted to the front After fitting the two mounting brackets the rack device can then be installed in...

Page 31: ...minimum clearances to neighboring devices Table 4 1 Minimum clearances for installation in rack devices Minimum clearance to devices below the switch 100 mm Minimum clearance to devices above the switch 100 mm NOTICE Four point mounting If mechanical load is high the device should be secured at four points You will find more detailed information in the section Mechanical stability in operation Mou...

Page 32: ... PLUG is on the right behind a protective panel secured with screws For more detailed information refer to the section on the C PLUG in the X 300 operating in structions The ventilation grilles are on the top bottom and sides of the housing You will find the diagnostics port of the device on the back of the housing for more detailed information refer to Diagnostics port XR 300 Mounting position fo...

Page 33: ...device The ventilation grilles are on the top bottom and sides of the housing The connectors for the signaling contacts and the power supply are on the rear of the device The Ethernet ports or the slots for the modules are on the rear of the device Slots for the modules are closed with dummy panels The C PLUG is on the right behind a protective panel secured with screws For more detailed informati...

Page 34: ... the rack device at the required height Make sure that nothing is obstructing air from entering the ventilation grilles Fit the securing screws to the two mounting brackets to secure the rack device in the 19 cabinet 5 Fit the connectors for the power supply Note that the SCALANCE X 300 is available for dif ferent power supplies 100 to 240 VAC and 24 VDC variants 6 Fit the remaining connectors for...

Page 35: ...ing The permitted device temperature of devices with a supply voltage of 100 to 240 VAC is exceeded in desktop operation Desktop operation is not permitted for devices with a supply voltage of 100 to 240 VAC Install devices with a supply voltage of 100 to 240 VAC in a rack Only use devices with a supply voltage of 24 to 48 VDC for desktop operation Procedure 1 Remove the foil from one side of the ...

Page 36: ... following problems Damage to the device Loss of the approvals Violation of the EMC regulations Use only approved media modules NOTICE Damage due to changing modules while the device is turned on Media modules for SCALANCE devices are not capable of hot plugging Install or remove media modules only when the power supply of the device is turned off Note Use media modules only in an approved modular...

Page 37: ...emperature is decided by the fully equipped device switch media module SFP transceiver With modular devices it is not only the switch that decides the permitted operating temperature of the overall device but also the temperature ranges of the MM900 media modules and the SFP transceivers You will find details in the technical specifications of the relevant components The following aspects can rest...

Page 38: ... device Note The figures in the following installation instructions show the installation of a media module in a rack device The procedure for installation is identical for rack or compact devices 1 Select the required slot on the device for example X308 2M Remove the dummy cover 2 Pull out the handle on the selected media module 3 Place the media module in the guide rails of the device slot The m...

Page 39: ...a module CAUTION Risk of burns due to the high temperature of the module housing Turn off the device and allow the device to cool down before you remove a media module 1 Remove all connectors from the media module 2 Pull out the handle of the media module and remove the media module from the device slot 3 Fir the dummy cover Spare parts Component Description Order number SCALANCE Cover Set Dummy c...

Page 40: ...pecification If you use unapproved SFPs this can lead to the following problems Damage to the device Loss of the approvals Violation of the EMC regulations Use only approved SFPs You can insert or remove the SFP during ongoing operation Inserting an SFP Note Only the media module MM992 2SFP may be fitted with approved SFPs The SFP media module can be fitted with up to two SFPs Device Media module ...

Page 41: ...losing the clip after insertion does not lock the device in the rack 3 The SFP can be heard to lock in place and is therefore firmly secured 4 Plug the connecting cable into the SFP The connecting cable can be heard to lock in place and is then firmly secured Removing an SFP 1 Remove the cable connected to the SFP 2 Open the clip on the SFP and remove the SFP from the SFP media module Notice It mu...

Page 42: ...Installation 4 8 Installation of modular devices SCALANCE XR 300M PoE 42 Compact Operating Instructions 05 2016 A5E02661178 10 ...

Page 43: ...y notices in addition to the general safety notices for protection against explosion WARNING EXPLOSION HAZARD DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLESS AREA IS KNOWN TO BE NON HAZARDOUS Safety notices for use according to ATEX and IECEx If you use the device under ATEX or IECEx conditions you must also keep to the following safety notices in addition to the general safety notices for protecti...

Page 44: ...ing open the redundant path before you insert a new or replacement device in an operational network A bad configuration or attachment of the Ethernet cables to incorrectly configured ports causes overload in the network and a breakdown in communication A device may only be inserted in a network and connected in the following situations HRP MRP The ring ports of the device being inserted in the rin...

Page 45: ...olts on the rear of the device To ground the device from the back follow the steps below 1 toothed washer 2 grounding bolt The connector for the grounding cable is in the center of the rear panel of the device Fit the toothed washer and tighten the grounding bolt with a maximum torque of 2 Nm 3 ground terminal with cable 4 washer 5 spring washer 6 nut Fit parts 3 4 and 5 as shown in drawing onto t...

Page 46: ...to 240 VAC The signaling contact is connected to a 2 pin plug in terminal block The signaling contact can be subjected to a maximum load of 100 mA safety extra low voltage SELV 24 V DC Table 5 1 Pin assignment of the 24 VDC signaling contact Pin number Assignment Pin 1 F1 Pin 2 F2 To wire up the signaling contact use a copper cable of category 18 12 AWG or cable with a cross section of 0 75 to 2 5...

Page 47: ...rt on the rear of the housing This port is designed for an RJ 11 plug A suitable connecting cable with an RJ 11 plug and a 9 pin D sub female connector for connection to the serial port of the PC ships with the SCALANCE XR 300 Diagnostics port on the rear of the device Pin assignment The following table shows the pin assignment of the RJ 11 plug and the D sub female connector Image 5 1 RJ 11 jack ...

Page 48: ...Ground 4 n c 5 RD Receive Data 5 SG Signal Ground 6 n c 6 n c 7 n c 8 n c 9 n c 5 5 Power supply 5 5 1 Power supply XR 300M PoE Power supply of the IE Switches XR 300M PoE WARNING Danger to life 100 to 240 VAC Please note that the IE Switches X 300PoE can have a 100 to 240 VAC or a 24 to 48 VDC power supply You can recognize the type of power supply from the labeling on the device and the labeling...

Page 49: ... low voltage SELV WARNING Safety extra low voltage The equipment is designed for operation with a directly connected safety extra low voltage SELV This does not apply to 100 V to 240 V devices The maximum current via the 24 V terminals is 8 A You should therefore include a fuse that trips at a current higher than 8 A The fuse must meet the following requirements Suitable for DC min 60 V max 8 A Br...

Page 50: ...00 without suitable overvoltage protection Connecting to the power supply SELV The power supply is connected using a 4 pin plug in terminal block The power supply can be connected redundantly Both inputs are isolated There is no distribution of load When a redundant power supply is used the power supply unit with the higher output voltage supplies the IE Switch X 300 alone The power supply is conn...

Page 51: ...oltage The supply voltage for the devices listed is 100 to 240 VAC This device can only function correctly and safely if it is transported stored set up and installed correctly and operated and maintained as recommended Connecting and disconnecting may only be performed by an electrical specialist Connect or disconnect power supply cables only when the power is turned off WARNING Devices with a 10...

Page 52: ... Danger from line voltage If used with cables with more than two wires correct functioning of the connector casing cannot be guaranteed because the two halves of the connector casing can come apart If this occurs you will also not be able to connect all the wires in the connector Open wire ends may be dangerous due to line voltage Use only two wire cables Procedure ...

Page 53: ...hten the cable tie The cable must be securely held in the lower part of the housing by the cable tie Cut off the excess cable tie 4 Fit the upper part of the housing The housing is correctly mounted when the two catches audibly click into place and are flush with the surface of the housing 5 5 3 4 Connecting the 100 to 240 V AC power supply Connecting to the power supply The devices have a single ...

Page 54: ...ent Description Order number Terminal block 2 pin 2 pin terminal block for power supply 100 to 240 VAC incl housing for SCALANCE XR300 pack of 5 6GK5980 1BC00 0AA5 Spare parts Component Description Order number Serial cable RJ 11 RS 232 preassembled serial cable with RJ 11 and RS 323 plug Length 5 m pack of 1 6GK5980 3BB00 0AA5 ...

Page 55: ...n Dimensions W x H x D 449 43 6 305 mm Weight 6800 g Degree of protection IP20 with closed service panel Table 6 2 Installation options Device version power supply Installation options 24 VDC 19 rack Desktop operation with adhesive feet 100 to 240 VAC 19 rack Table 6 3 Permitted ambient conditions Storage transport temperature 40 C to 85 Max relative humidity in operation at 25 C 95 no condensatio...

Page 56: ...ansceiver SFP991 1 SFP991 1LD SFP992 1 SFP992 1LD Horizontal 40 C to 60 Vertical 40 C to 50 Media module MM992 2SFP with pluggable transceiver SFP991 1LH SFP992 1LH SFP992 1LH SFP992 1ELH SFP991 1ELH200 Horizontal Maximum 2 modules in slots 3 and 4 40 C 60 C With more than 2 modules or other slot assign ment 40 C to 50 C Vertical 40 C to 50 MM991 2P Maximum 2 modules in slots 3 and 4 The slot abov...

Page 57: ... 2 ports per slot Transmitter output optical and receiver input The values correspond to those of the permitted MM900 media modules and SFP transceivers Diagnostics port RJ 11 jack Table 6 6 Electrical data Power supply Device version power supply Redundant power supply unit Redundant power supply possible Power supply 24 VDC No Yes Rated voltage 24 VDC Voltage range 19 2 VDC 28 8 VDC Permitted vo...

Page 58: ... signaling contact Device version power supply Power supply Signaling contact 24 VDC 1 x 4 pin 1 x 2 pin 100 to 240 VAC 1 x 2 pin 1 x 2 pin Table 6 11 Power over Ethernet at port P1 to P8 PoE function within a power supply system According to IEEE 802 3af 802 3at type 1 for environment A Method of PoE power feed Alternative A refer to the following table for the pin assign ment Reserved power per ...

Page 59: ... pair cables the wires are connected to pins 1 2 3 and 6 6 3 Cable lengths Table 6 14 Permitted cable lengths copper cable Fast Ethernet Cable type Accessory plug outlet TP cord Permitted cable length IE TP torsion cable with IE FC Outlet RJ 45 10 m TP cord 0 to 45 m 10 m TP cord with IE FC RJ 45 Plug 180 0 to 55 m IE FC TP Marine Cable IE FC TP Trailing Cable IE FC TP Flexible Cable with IE FC Ou...

Page 60: ... to 90 m 10 m TP cord Note Permitted cable lengths fiber optic cable Fast Ethernet or gigabit The values correspond to those of the permitted MM900 media modules and SFP transceivers Block architecture of the SCALANCE XR 300M PoE The XR 300M PoE handles the Ethernet frame traffic of the 24 ports with the aid of three switch blocks The three switch blocks are connected in series block 1 via block 2...

Page 61: ...5 μs Table 6 17 Reconfiguration times for redundancy mechanisms Redundancy mechanism Reconfiguration times HRP 300 ms Standby link 300 ms MRP 200 ms Mean time between failure MTBF The value in the following table applies to the basic device without media modules MTBF 15 years 1 1 This value applies at 40 C In the calculation of the MTBF of a modular switch the standard parts count applies in other...

Page 62: ...024 bytes 9615 96154 1280 bytes 8127 81274 1518 bytes Note The following applies to IE Switches X 300 The number of IE Switches X 300 connected in a line influences the frame delay time When a frame passes through the switch this is delayed by the Store Forward function of the IE Switch X 300 by the following values at 64 bytes frame length Delay of approx 10 microseconds at 100 Mbps at 1500 bytes...

Page 63: ... 05 2016 A5E02661178 10 63 Dimension drawings 7 All dimensions in the drawings are in millimeters Image 7 1 XR324 4M PoE and XR324 4M PoE TS Front view Image 7 2 XR324 4M PoE and XR324 4M PoE TS Side view Image 7 3 XR324 4M PoE and XR324 4M PoE TS Rear ...

Page 64: ...Dimension drawings SCALANCE XR 300M PoE 64 Compact Operating Instructions 05 2016 A5E02661178 10 Image 7 4 XR324 4M PoE and XR324 4M PoE TS From above ...

Page 65: ...of the following EC directives EMC directive electromagnetic compatibility The SIMATIC NET products described in these operating instructions meet the requirements of EC directive 2004 108 EC Electromagnetic Compatibility for the following areas of application Field of application Requirements Emission Immunity to interference Industry EN 61000 6 4 2007 EN 61000 6 2 2005 WARNING Personal injury an...

Page 66: ...port automation siemens com WW view en 60612658 Working on the device To protect the device from electrostatic discharge personnel must first discharge any electrostatic charge from their body before touching the device Note The test was performed with a device and a connected communications partner that also meets the requirements of the standards listed above When operating the device with a com...

Page 67: ...rements of this approval C Tick The product meets the requirements of the AS NZS 2064 standard Class A cULus Approval for Information Technology Equipment cULus Listed I T E Underwriters Laboratories Inc complying with UL 60950 1 Information Technology Equipment CSA C22 2 No 60950 1 03 Report no E115352 Note Only variants with 24 VDC power supply meet the requirements of this approval cULus approv...

Page 68: ...requirements of the Railway standard EN 50155 2007 Railway Applications Electronic equipment used on rolling stock Note When used on railway stock a stabilized power supply must be used to comply with EN50155 8 2 SCALANCE X 300 declaration of conformity You will find the EC Declaration of Conformity for these products on the Internet at the following address SCALANCE X 300 declaration of conformit...

Page 69: ...0 to 240 VAC XR324 4M PoE TS 1 x 24 VDC 1 For temperature information T or the maximum ambient temperature Ta refer to the type plate 8 4 Mechanical stability in operation The switch meets the following requirements for mechanical stability IEC 60068 2 6 vibration Mounting in the rack 2 point mounting 10 to 58 Hz 0 075 mm 85 150 Hz 1 g 1 octave min 20 sweeps Individual mounting 4 point mounting 5 ...

Page 70: ...Approvals 8 4 Mechanical stability in operation SCALANCE XR 300M PoE 70 Compact Operating Instructions 05 2016 A5E02661178 10 ...

Page 71: ...mental conditions dust dampness Due to the locking technology standardized for the M12 connectors a high resistance to vibration is achieved Numerous SCALANCE devices therefore provide connection options for X coded M12 connectors Pin assignment A Front view of M12 connector X coded according to IEC61076 2 109 B Front view of RJ 45 connector latching nose at the top with pin assignment according t...

Page 72: ...Appendix A 1 The connector system M12 X coded according to IEC 61076 2 109 SCALANCE XR 300M PoE 72 Compact Operating Instructions 05 2016 A5E02661178 10 ...

Page 73: ...ting Instructions 05 2016 A5E02661178 10 73 Index A ATEX 11 G Glossary 6 H Hazardous Ex area 11 S Safety instructions 9 Safety notices for installation 27 general 9 Use in hazardous areas 9 27 SIMATIC NET glossary 6 System manual 29 66 ...

Page 74: ...Index SCALANCE XR 300M PoE 74 Compact Operating Instructions 05 2016 A5E02661178 10 ...

Reviews: