Connecting
5.4 Signaling contact
SCALANCE XR-500
66
Operating Instructions, 05/2017, A5E03275845-11
Position and assignment
Figure 5-10 Position of the signaling contact on a SCALANCE XR524-8C SCALANCE XR526-8C is
analogous.
Figure 5-11 Position of the signaling contact on a SCALANCE XR552-12M. SCALANCE XR528-6M
is analogous.
Signaling faults
●
The signaling of errors/faults by the signaling contact is synchronized with the fault LED
"F". All faults/errors indicated by the fault LED "F" (freely configurable) are also signaled
by the signaling contact.
●
If an internal fault occurs, the fault LED "F" lights up and the signaling contact opens.
●
If you connect a communications node to an unmonitored port or disconnect it, this does
not cause an error message.
●
The signaling contact remains open until one of the following events occurs:
–
The problem is eliminated.
–
The current status is entered in the fault mask as the new desired status.