Certification
10.1 FDA and IEC marks
SCALANCE XR-500
108
Operating Instructions, 05/2017, A5E03275845-11
10.1
FDA and IEC marks
The following devices meet the FDA and IEC requirements listed below:
Device
Fulfills FDA and IEC requirements
SCALANCE XR524-8C
-
SCALANCE XR526-8C
-
SCALANCE XR528-6M
-
SCALANCE XR552-12M
-
Note: With modular devices , the marking is on the MM900 media modules and the SFP and SFP+ transceivers.
Figure 10-1 FDA and IEC approvals
10.2
Mechanical stability (in operation)
Device
IEC 60068-2-6 vibration *
IEC 60068-2-6 vibration
IEC 60068-2-27 shock
5 - 9 Hz: 3.5 mm
9 - 150 Hz: 1 g
1 octave/min, 20 sweeps
10 - 58 Hz: 0.075 mm
85 - 150 Hz: 1 g
1 octave/min, 20 sweeps
15 g, 11 ms duration
6 shocks per axis
SCALANCE XR524-8C
●
●
●
SCALANCE XR526-8C
●
●
●
SCALANCE XR528-6M
●
●
●
SCALANCE XR552-12M
●
●
●
" When rack mounted with four securing points
Installation guidelines
The devices meet the requirements if you adhere to the installation and safety instructions
contained in this documentation and in the following documentation when installing and
operating the devices.
●
"Industrial Ethernet / PROFINET Industrial Ethernet" System Manual
●
"Industrial Ethernet / PROFINET - Passive network components" System Manual
You will find information on the system manuals in the section "Introduction (Page 5)", in
"Further documentation".
●
"EMC Installation Guidelines" configuration manual
60612658 (