IEC 60068-2-6 vibration
IEC 60068-2-27 shock
IEC 60068-2-6 vibration *)
10 – 58 Hz: 0.15 mm
58 – 500 Hz: 1 g
1 octave/min,
10 cycles
15 g, 11 ms duration
6 shocks per axis
5 – 8.51 Hz: 7 mm
8.51 – 500 Hz: 1 g
1 octave/min,
10 cycles
XR324-12M
(1 x 100 to 240 VAC, data cable
outlet at rear)
●
●
●
*) Note: When rack mounted with 4 securing points
Installation guidelines
The devices meet the requirements if you adhere to the installation and safety instructions
contained in this documentation and in the following documentation when installing and
operating the devices.
● "Industrial Ethernet / PROFINET Industrial Ethernet" System Manual (
support.industry.siemens.com/cs/ww/en/view/27069465
● "Industrial Ethernet / PROFINET - Passive Network Components" System Manual (
support.industry.siemens.com/cs/ww/en/view/84922825
● "EMC Installation Guidelines" configuration manual (
https://support.industry.siemens.com/
)
WARNING
Personal injury and property damage can occur
The installation of expansions that are not approved for SIMATIC NET products or their target
systems may violate the requirements and regulations for safety and electromagnetic
compatibility.
Only use expansions that are approved for the system.
Note
The test was performed with a device and a connected communications partner that also meets
the requirements of the standards listed above.
When operating the device with a communications partner that does not comply with these
standards, adherence to the corresponding values cannot be guaranteed.
Approvals
9.1 XR-300M mechanical stability (in operation)
SCALANCE XR-300M
78
Compact Operating Instructions, 11/2019, A5E02661171-15
Summary of Contents for SCALANCE XR-300M
Page 10: ...Introduction SCALANCE XR 300M 10 Compact Operating Instructions 11 2019 A5E02661171 15 ...
Page 12: ...Safety notices SCALANCE XR 300M 12 Compact Operating Instructions 11 2019 A5E02661171 15 ...
Page 82: ...Index SCALANCE XR 300M 82 Compact Operating Instructions 11 2019 A5E02661171 15 ...