![Siemens SCALANCE XR-300M Compact Operating Instructions Download Page 77](http://html.mh-extra.com/html/siemens/scalance-xr-300m/scalance-xr-300m_compact-operating-instructions_383840077.webp)
Note
When used on railway stock, a stabilized power supply must be used to comply with EN50155.
FDA and IEC marking
The following devices meet the FDA and IEC requirements listed below:
Device
CLASS 1 LASER Product
SCALANCE XR324-12M
(*)
SCALANCE XR324-12M
(*)
SCALANCE XR324-12M
(*)
SCALANCE XR324-12M
(*)
* For modular devices, you can find the marking in the operating instructions for the media module or
plug-in transceiver used.
&RPSOLHVZLWK&)5
DQG
&/$66/$6(5352'8&7
)'$
,(&
Figure 9-1
FDA and IEC approvals
CAUTION
Use of controls or adjustments or performance of procedures other than those specified
herein may result in hazardous radiation exposure.
9.1
XR-300M mechanical stability (in operation)
Device:
SCALANCE
(Variant)
IEC 60068-2-6 vibration
IEC 60068-2-27 shock
IEC 60068-2-6 vibration *)
10 – 58 Hz: 0.15 mm
58 – 500 Hz: 1 g
1 octave/min,
10 cycles
15 g, 11 ms duration
6 shocks per axis
5 – 8.51 Hz: 7 mm
8.51 – 500 Hz: 1 g
1 octave/min,
10 cycles
XR324-12M
( 2 x DC data cable outlet on
front)
●
●
●
XR324-12M
(1 x 100...240 VAC, data cable
outlet on front)
●
●
●
XR324-12M
( 2 x 24 VDC data cable outlet at
rear)
●
●
●
Approvals
9.1 XR-300M mechanical stability (in operation)
SCALANCE XR-300M
Compact Operating Instructions, 11/2019, A5E02661171-15