Connecting up
4.6 Serial interface
SCALANCE XP-200
62
Operating Instructions, 05/2016, C79000-G8976-C428-01
4.6
Serial interface
Information on the serial interface
●
To connect the serial interface, the device has an M12 interface: A-coded, 5-pin, female.
●
Via the serial interface, you can access the CLI of the device directly via an RS-232
connection (115200 8N1) without assigning an IP address.
●
Access to the device is also possible independent of the Ethernet ports.
●
To connect the serial interface to the PC, you require a cable with an M12 plug and 9-pin
D-sub female connector. You can order the connecting cable for the serial interface as an
accessory.
●
When it ships, the cover for the serial interface is secured to the housing see "Device
Position and assignment
Figure 4-4
Position and pin assignment of the serial interface, for example on the SCALANCE
XP208
Pin number
Assignment
1
TD (Transmit Data)
2
RD (Receive Data)
3
internal use only (do not connect)
4
SG (Signal Ground)
5
internal use only (do not connect)