Description of the device
2.6 C-PLUG
SCALANCE XP-200
38
Operating Instructions, 05/2016, C79000-G8976-C428-01
Operation with C-PLUG
The configuration stored on the C-PLUG is displayed over the user interfaces.
If changes are made to the configuration, the device stores the configuration directly on the
C-PLUG, if this is in the "ACCEPTED" status and in internal memory.
Response to errors
Inserting a C-PLUG that does not contain the configuration of a compatible device type and
inadvertently removing the C-PLUG, or general malfunctions of the C-PLUG are indicated by
the diagnostic mechanisms of the device.
●
Fault LED
●
Web Based Management (WBM)
●
SNMP
●
Command Line Interface (CLI)
●
PROFINET diagnostics
The user then has the choice of either removing the C-PLUG again or selecting the option to
reformat the C-PLUG.
2.6.2
Replacing the C-PLUG
Position of the C-PLUG
NOTICE
Loss of water and dust protection
If the cover is not mounted correctly, the device is not water and dust proof.
NOTICE
Loss of the railway approval
If you use an unvarnished C-PLUG, the device does not comply with the railway standard
EN50155.
NOTICE
Do not remove or insert a C-PLUG during operation
The C-PLUG may only be removed or inserted when the device is turned off.
The device checks whether or not a C-PLUG is inserted at one second intervals. If it is
detected that the PLUG was inserted or removed, there is a restart.