Diagnostics
12.5 RMON
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
943
The parameters have the following meaning:
Parameter
Description
Range of values / note
index
Number of the recording
1 ... 65535
buckets
Maximum number of recording inter-
vals
-
bucket-number
Number of recording intervals
1 ... 65535
Default: 50
interval
Duration of an individual recording
interval
-
seconds
Time in seconds
1 ... 3600
Default: 1800
owner
User to which the event is assigned
-
ownername
User name of the user
max. 127 characters
Default: monitor
If you do not select any parameter from the parameter list, the default values are used.
Result
The data is recorded.
Further notes
You can display the content of a recording with the
show rmon history
command.
12.5.3.4
no rmon collection history
Description
With this command, you end the recording of statistical data of the interface.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
no rmon collection history <index(1-52)>