![Siemens SCALANCE XM-400 Configuration Manual Download Page 107](http://html.mh-extra.com/html/siemens/scalance-xm-400/scalance-xm-400_configuration-manual_382069107.webp)
Configuration
3.1 System
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
107
Requirement
●
The interface is disabled with the
shutdown
command.
●
You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
no switchport
Result
The interface is configured as a router port.
The command prompt is as follows:
cli(config-if_RPort-Gi$$$)#
Activate the interface again with the
no shutdown
command.
Further notes
You shut down the interface with the
shutdown
command.
You activate the interface with the
no shutdown
command.
You configure the interface as a switch port with the
switchport
command.
You can display the status of this function and other information with the
show ip
interface
command.
3.1.13.22
unicast-block
Description
With this command, you enable the blocking of unknown unicast frames on an interface.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameter assignment:
unicast-block