Further notes
You enable this function with the
panel-button control-faultmask
command.
4.3.1.5
panel-button control-hsr-manager
Description
With this command, you enable the following function of the button:
● If display mode B is displayed and the button is pressed for 5 seconds, the "redundancy
manager" function is switched over.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameter assignment:
panel-button control-hsr-manager
Result
The function of the button for switching over the redundancy manager is enabled.
Further notes
You disable this function with the
no panel-button control-hsr-manager
command.
4.3.1.6
no panel-button control-hsr-manager
Description
With this command, you disable the following function of the button:
● If display mode B is displayed and the button is pressed for 5 seconds, the "redundancy
manager" function is switched over.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
Functions specific to SCALANCE
4.3 Panel button
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06
137