5.2
Mounting on DIN rails
Installation
To install the devices on a 35 mm DIN rail complying with DIN EN 60715, follow the steps
below:
1. Fit the upper part of the locking mechanism of the device on to the DIN rail.
2. Press the device down against the DIN rail until it locks into place.
3. Fit the connectors for the power supply.
4. Fit the connectors for the signaling contact.
5. Insert the terminal blocks into the sockets on the device.
Figure 5-1
Mounting on a 35 mm DIN rail based on the example of a SCALANCE X204RNA EEC
Installation
5.2 Mounting on DIN rails
SCALANCE X-200RNA
Operating Instructions, 10/2016, C79000-G8976-C342-04
57