4.8.1.5
Mode LED (SCALANCE X204RNA EEC (PRP/HSR))
The SCALANCE X204RNA EEC (PRP/HSR) has the labeling of both devices on its housing,
in other words, that of the SCALANCE X204RNA EEC (PRP) and the SCALANCE X204RNA
EEC (HSR). Depending on how you configure the SCALANCE X204RNA EEC (PRP/HSR),
the labeling is valid as described in the sections above.
The exception is the mode LED (third LED from the top):
● When the LED is lit, the SCALANCE X204RNA EEC (PRP/HSR) is in HSR mode. This
means that the right-hand labeling of the LED displays applies. The device behaves like a
SCALANCE X204RNA EEC (HSR).
● When the LED is not lit, the SCALANCE X204RNA EEC (PRP/HSR) is in PRP mode. This
means that the left-hand labeling of the LED displays applies. The device behaves like a
SCALANCE X204RNA EEC (PRP).
4.8.2
SCALANCE X-200RNA (HSR)
4.8.2.1
Fault LED
If the LED is lit red, a SCALANCE X-200RNA (HSR) has detected an error/fault.
At the same time, the signaling contact opens assuming that the response of the signaling
contact has not been configured differently.
The LED signals that the SCALANCE X-200RNA (HSR) can adopt the following statuses:
Device type SCALANCE
LED lit red
LED lit yellow
LED not lit
X204RNA (HSR)
1, 2, 3, 4, 5, 6
7
8
X204RNA EEC (HSR)
1, 3, 4, 5, 6
7
8
X204RNA EEC (PRP/HSR)
If configured as HSR device.
1, 3, 4, 5, 6
7
8
1. Link down event on a monitored port.
2. Failure of one of the two redundant power supplies.
3. C-PLUG error.
4. Device startup, the LED is lit for approx. 20 seconds.
5. Internal error.
6. A redundancy error has been detected (unexpected frames via HSR1, HSR2, P1/A or P2/
B ports).
7. Redundancy warning (incorrect LAN ID at P1/A or P2/B)
8. No problem has been detected by the SCALANCE X-200RNA (HSR).
4.8.2.2
Power LED
The LEDs signal the following statuses of the SCALANCE X-200RNA (HSR).
Descriptions of the products
4.8 LEDs
SCALANCE X-200RNA
Operating Instructions, 10/2016, C79000-G8976-C342-04
51
Summary of Contents for SCALANCE X-200RNA
Page 6: ...Table of contents SCALANCE X 200RNA 6 Operating Instructions 10 2016 C79000 G8976 C342 04 ...
Page 12: ...Introduction SCALANCE X 200RNA 12 Operating Instructions 10 2016 C79000 G8976 C342 04 ...
Page 16: ...Safety notices SCALANCE X 200RNA 16 Operating Instructions 10 2016 C79000 G8976 C342 04 ...