4.7
SELECT/SET button
Function of the SELECT/SET button
With the SELECT/SET button, you can change various settings of the device. Modified settings
are retained after device power off/on.
The SELECT/SET button is used to switch over the display mode and to make other settings.
After turning on the SCALANCE X-200RNA, it is in the display mode.
The SELECT/SET button has three functions:
● Triggering a device restart
● Reset to the factory defaults All settings made are overwritten by the factory defaults.
● Define the fault mask and the display at the LEDs. The current states of all ports and the
states of the power supplies L1 and L2 are included in the "X200 Fault Mask Power" dialog
box. The previous fault mask is then overwritten.
Different settings are made depending on how long you hold down the SELECT/SET button:
Figure 4-8
The five button phases
Time the button is pressed in seconds
Table 4-6
Button phases
Phase
Description
1
The currently set fault mask is displayed. If no fault mask has been set, all ports flash one after the other.
If you release the SELECT/SET button in phase 1, this has no effect.
2
The LEDs of the ports at which there is currently a link flash at 2.5 Hz.
If you release the SELECT/SET button in phase 2, this has no effect.
3
The LEDs of the ports at which there is currently a link and the LEDs of the connected power supply are lit
permanently.
If you release the button in phase 3, the fault mask corresponding to the lit LEDs is adopted.
4
All port LEDs flash at 2.5 Hz.
Releasing the SELECT/SET button during this phase brings about a device restart (soft reset)
5
All port LEDs flash alternately yellow/green at 2.5 Hz.
The device is reset to the factory defaults.
Descriptions of the products
4.7 SELECT/SET button
SCALANCE X-200RNA
46
Operating Instructions, 10/2016, C79000-G8976-C342-04
Summary of Contents for SCALANCE X-200RNA
Page 6: ...Table of contents SCALANCE X 200RNA 6 Operating Instructions 10 2016 C79000 G8976 C342 04 ...
Page 12: ...Introduction SCALANCE X 200RNA 12 Operating Instructions 10 2016 C79000 G8976 C342 04 ...
Page 16: ...Safety notices SCALANCE X 200RNA 16 Operating Instructions 10 2016 C79000 G8976 C342 04 ...