interval
Use the
interval
command to configure the push interval in minutes. This command is available from
the location:publish context.
interval minutes
Parameters
minutes
Specifies the number of minutes for the push interval. Valid values are: 1, 2, 5, 10, 20,
30, 60, 120, or 240 minutes.
Usage
Location push must be enabled using the
push enable
command for the interval command to take
affect.
Examples
The following example sets the location push interval to 30 minutes:
WLC.siemens.com
:location:publish# interval 30
unit
Use the
unit
command to set the location push unit to either meters or feet. This command is available
from the location:publish context.
unit (0 | 1)
Parameters
0
|
1
Specifies whether the push unit is in meters (0) or feet (1).
Examples
The following example sets the push unit to meters:
WLC.siemens.com
:location:publish# unit 0
push-list
Use the
push-list
command to configure a push URL list. This command is available from the
location:publish context.
push-list [add | delete] url [url]*>