cli(config-events)#
Syntax
Call up the command with the following parameters:
no link {up|down}
The parameters have the following meaning:
Parameters
Description
Range of values / note
up
The message when establishing a connection is dis‐
abled
-
down
The message when a connection is down is disabled -
Result
The settings for monitoring the physical network connections have been configured.
Further notes
You can display the current setting with the
show events faults config
command.
You enable the function with the
link
command.
12.1.6.8
power
Description
With this command, you configure and activate the monitoring of the power supplies.
Depending on the hardware variant there are one or two power connectors (L 1 / L 2) and a
PoE power supply.
Note
This command is not available on the SCALANCE W786-2 SFP.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
power [{l1 | l2 | poe}]