5.3.3
wlan signal-recorder stop (client)
Description
With this command, you stop the recording with the signal recorder.
Note
This command is only available in the client mode.
Requirement
● A recording was started.
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli>
or
cli#
Syntax
● The WLAN interface is enabled.
Call up the command with the following parameters:
wlan signal-recorder <wlan 0/X> stop
The parameter has the following meaning:
Parameter
Description
Range of values / note
wlan 0/X
WLAN interface
Enter a valid interface.
For information on identifiers of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 29)".
Result
The recording was stopped.
Further notes
You start the recording with the
wlan signal-recorder start
command.
Functions specific to SCALANCE
5.3 Signal recorder
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08
119