SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
403
Diagnostics
11
The monitoring of the system and error diagnostics are handled in different ways:
●
Events and faults handling:
Predefined events generate a message. These messages can be distributed in different
ways:
–
Entry in the local log
–
Transfer to the Syslog server
–
Sending as e-mail
–
Sending as SNMP trap
●
Syslog:
Configures the transfer to the Syslog server
●
Port mirroring:
Mirroring of ports to analyze the data stream without disturbing operation
11.1
Diagnostics
In events and faults handling, you set the events whose messages will be distributed in one
of the available ways.
You configure the monitoring of certain system events and power supply and physical
interfaces in the Events configuration mode.
11.1.1
show authlog
Description
With this command, you show the information about successful or failed authentication
attempts.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli>
or
cli#