![Siemens SCALANCE S615 Configuration Manual Download Page 65](http://html.mh-extra.com/html/siemens/scalance-s615/scalance-s615_configuration-manual_377351065.webp)
Configuration
2.1 System
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
65
Result
The automatic negotiation of connection parameters on an interface is deactivated.
Further notes
You enable the autonegotiation of connection parameters with the
negotiation
command.
2.1.10.9
mtu
Description
With this command, you configure the size of the Maximum Transmission Unit (MTU) for an
interface.
Requirement
●
The Interface must be shut down.
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
mtu <frame-size(64-1500)>
The parameter has the following meaning:
Parameter
Description
Range of values
frame-size
Size of the MTU in bytes
64 ... 1500
At system start or when using the
restart
command with the option
memory
or
factory
, the
following defaults apply:
●
The size of the MTU is configured to 1536 bytes.
Result
The setting for the size of the MTU is configured.
Further notes
You can shut down the interface with the
shutdown complete
command.
You display this setting with the
show interface mtu
command.
You display this setting and other information with the
show interfaces
command.