![Siemens SCALANCE S615 Configuration Manual Download Page 202](http://html.mh-extra.com/html/siemens/scalance-s615/scalance-s615_configuration-manual_377351202.webp)
Network protocols
6.4 DHCP server
SCALANCE S615 Command Line Interface
202
Configuration Manual, 06/2015, C79000-G8976-C406-02
The parameters have the following meaning:
Parameter
Description
Range of values / note
option-code
Code of the DHCP option
Enter a valid DHCP option.
The following DHCP options are not sup-
ported:
•
50 - 60
•
255
dhcp-param
DHCP parameter in hexadecimal
Enter a valid hexadecimal value.
Format: XXXXX e.g. C0A86402
Result
The DHCP option is configured. In total a maximum of 20 DHCP options are possible.
Further notes
You display the setting with the
show ip dhcp-server-pools
command.
You disable the IPv4 address band with the
no pool-enable
command.
You delete the DHCP option with the
no option
command.
6.4.3.6
pool-enable
Description
With this command you specify that this IPv4 address band will be used.
Requirement
You are in the DHCPPOOL configuration mode.
The command prompt is as follows:
cli(config-dhcp-pool-<ID>)#
Syntax
Call the command without parameter assignment:
pool-enable