Network structures
5.1 VLAN
SCALANCE S615 Command Line Interface
140
Configuration Manual, 06/2015, C79000-G8976-C406-02
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 25)".
If you do not select any parameter from the parameter list, all entries are displayed.
Result
The entries are displayed.
5.1.1.2
show vlan
Description
This command shows the specific information for all or a selected VLAN.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli>
or
cli#
Syntax
Call up the command with the following parameters:
show vlan[brief|id<vlan-range>|summary]
The parameters have the following meaning:
Parameter
Description
Range of values / note
brief
Shows brief information about all
VLANs
-
id
Keyword for a VLAN or VLAN range
-
vlan-range
Number of the addressed VLAN or
VLAN range
1 ... 4094
summary
Shows a summary of the VLANs
If you do not select any parameter from the parameter list, the entries of all available
interfaces are displayed.
Result
The information for the selected VLAN is displayed.