Technical specifications
7
SCALANCE M826-2
Article number
6GK5 826-2AB00-2AB2
Ethernet interface
Attachment to Industrial Ether‐
net
Quantity
4
Design
RJ-45 jack
Characteristics:
• 10/100BASE-T
• Ethernet IEEE 802
• 10/100 Mbps
WAN interface
DSL connection
Quantity
2
Design
Terminal block, 2 terminals
G.SHDSL
G.SHDSL.bis
Properties
ITU-T G.991.2.bis
Transmission speed
2-wire mode: up to 15.3 Mbps
4-wire mode (aggregated): up to 30 Mbps
Electrical data
Power supply
Input voltage
12 to 24 VDC
min. 10.8 VDC, max. 28.8 V
Maximum power con‐
sumption
7 W
Digital input
Quantity
1
Design
Terminal block, 2 terminals
Characteristics:
Rated voltage 24 VDC Safe Extra Low Volt‐
age (SELV)
For state "1": 13 to 30 VDC
For state "0": -30 to 3 VDC
Maximum input current 8 mA
Cables should be routed in pairs
Maximum cable length < 30 m
Inputs isolated from electronics.