4.6
Installing on the S7-1500 standard rail
Installation
1. Place the first housing guide of the device on the top edge of the standard rail
①
.
2. Using a screwdriver, pull down the catch
②
on the rear of the device.
3. Swing the device down while pressing the catch
③
. After it is released, the spring catch locks
in place.
4. Connect the power supply, refer to the section "Power supply (Page 45)".
5. Fit the connectors for the digital input and digital output, refer to the section "Digital input/
6. Connect the device to the DSL connection, refer to the section "SHDSL connection
(Page 49)".
7. Connect the device to the local network, refer to the section "Ethernet port (Page 53)".
8. Connect the terminal with as short a cable as possible ≤ 150 mm and a large cross-sectional
area of 1.5 mm² to the functional ground of the system, see section "Terminals (Page 23)“ and
section “Grounding (Page 46)“.
Dismantling
1. Disconnect all connected cables.
2. Using a screwdriver, pull down the catch on the rear of the device.
3. Remove the device from the standard rail.
Installation and removal
4.6 Installing on the S7-1500 standard rail
SCALANCE M826