Installation
1. Prepare the drill holes for wall mounting. For the precise dimensions, refer to the section
"Dimension drawings".
2. Secure the device to the wall with two screws. When mounting on a wall, use mounting
fittings suitable for the type of wall.
3. Connect the power supply, refer to the section "Power supply (Page 45)".
4. Fit the connectors for the digital input and digital output, refer to the section "Digital input/
5. Connect the device to the DSL connection, refer to the section "SHDSL connection
(Page 49)".
6. Connect the device to the local network, refer to the section "Ethernet port (Page 53)".
7. Connect the terminal with as short a cable as possible ≤ 150 mm and a large cross-sectional
area of 1.5 mm² to the functional ground of the system, see section "Terminals (Page 23)“ and
section “Grounding (Page 46)“.
See also
Installation and removal
4.3 Wall mounting
SCALANCE M826
Operating Instructions, 10/2022, C79000-G8976-C362-07
35