Chapter 5
Certification
RUGGEDCOM WIN7258
Installation Guide
38
RoHS
•
IEEE 1613
IEEE Standard Environmental and Testing Requirements for Communications Networking Devices in Electric
Power Substations
•
IEC 61850-3
General Requirements
•
IEC 870-2-2
Telecontrol Equipment and Systems – Part 2: Operating Conditions – Section 2: Environmental Conditions
(Climatic, Mechanical and Other Non-Electrical Influences)
•
MIL-STD-810F
Department of Defense Test Method Standard for Environmental Engineering Considerations and Laboratory
Tests – Method 509.4 (Salt Fog)
Section 5.1.7
RoHS
This device is declared by Siemens Canada Ltd to meet the requirements of the following RoHS (Restriction of
Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic
equipment:
•
China RoHS 2
Administrative Measure on the Control of Pollution Caused by Electronic Information Products
A copy of the Material Declaration is available online at
https://support.industry.siemens.com/cs/ww/en/
Section 5.2
EMC and Environmental Type Tests
The RUGGEDCOM WIN7258 has passed the following Electromagnetic Compatibility (EMC) and environmental
tests.
EMC Type Test for IEC 61850-3
Standard
Method
Description
Test Levels
Climatic Environmental Conditions
IEC 60068-2-1
IEC 61850-3 (5.2)
Low Temperature (Operational)
-40 °C (-40 °F), 16 Hour Dwell
IEC 60068-2-2
IEC 61850-3 (5.2)
High Temperature (Operational)
-65 °C (-149 °F), 16 Hour Dwell
IEC 60068-2-1
IEC 61850-3 (5.2)
Low Temperature (Storage)
-40 °C (-40 °F), 16 Hour Dwell
IEC 60068-2-2
IEC 61850-3 (5.2)
High Temperature (Storage)
-65 °C (-149 °F), 16 Hour Dwell
IEC 60068-2-30
IEEE 61850-3 (5.2)
Humidity (Operational)
95% at 55 °C (131 °F) for 96 Hours
IEC 60068-2-30
IEEE 61850-3 (5.2)
Humidity (Storage)
95% at 55 °C (131 °F) for 96 Hours
Mechanical Environmental Conditions
IEC 60068-2-27
IEC 61850-3 (5.5)
Shock
30 g (965 ft/s
2
)