RUGGEDCOM ROX II
User Guide
Chapter 3
Device Management
Using Microsoft IIS Manager 6.0 or Higher as an Upgrade
Server
61
Section 3.11.2.2
Using Microsoft IIS Manager 6.0 or Higher as an Upgrade Server
When using Microsoft Internet Information Services (IIS) Manager 6.0 or higher as an upgrade server, a new
application/octet-stream MIME type named "*" must be added to the IIS properties. This is required for IIS to
consider ROX II upgrade packets as an application/octet-stream, otherwise ROX II upgrades will fail.
To add the new MIME type to the IIS properties, do the following:
1. In the Windows
Start
menu, right-click on
My Computer
and select
Manage
. The
Computer Management
dialog appears.
2. Under
Services and Applications
, locate the
Internet Information Services (IIS) Manager
node. Right-
click on your ROX upgrade repository website and select
Properties
. The
Properties
dialog appears.
3. Select the
HTTP Headers
tab and click
MIME Types
. The
MIME Types
dialog appears.
4. Click
New
. The
MIME Type
dialog appears.
5. In the
Extension
field, type
*
.
6. In the
MIME type
field, type
application/octet-stream
.
7. Click
OK
on the
MIME Type
,
MIME Types
, and
Properties
dialog boxes.
Section 3.11.3
Upgrading the ROX II Software
ROX II software upgrades are managed between two partitions. One partition is always active, while the other is
always inactive. Software upgrades are always applied to the inactive partition. This allows the active partition to
function normally during a software upgrade and for users to roll back a software upgrade to previous version.
After a successful software upgrade and reboot, the upgraded partition is activated.
IMPORTANT!
When a USB Mass Storage drive is used, do not remove the drive during the file transfer.
NOTE
All parameters are locked during a software upgrade until the device is rebooted and the upgraded
partition is changed to an active state. This prevents post-upgrade configuration changes that are not
carried over to the upgraded partition.
If required, the software upgrade can be stopped/declined at any time before the device is rebooted.
For more information about stopping/declining a software upgrade, refer to
.
NOTE
All system configurations and user files (i.e. feature keys, configuration files, etc.) are carried over to
the upgrade partition.
NOTE
If a major system failure is detected upon rebooting with the newly upgraded partition, the device will
automatically roll back to the previously active partition.
To upgrade the ROX II software, do the following:
Summary of Contents for RUGGEDCOM RX1510
Page 32: ...RUGGEDCOM ROX II User Guide Preface Customer Support xxxii ...
Page 44: ...RUGGEDCOM ROX II User Guide Chapter 1 Introduction User Permissions 12 ...
Page 62: ...RUGGEDCOM ROX II User Guide Chapter 2 Using ROX II Using the Command Line Interface 30 ...
Page 268: ...RUGGEDCOM ROX II User Guide Chapter 4 System Administration Deleting a Scheduled Job 236 ...