Chapter 6
Certification
RUGGEDCOM RX1000
Installation Guide
42
EMI and Environmental Type Tests
Section 6.4
EMI and Environmental Type Tests
The RX1000 has passed the following EMI and environmental tests.
IEC 61850-3 EMI Type Tests
NOTE
• In the case of an all fiber port configuration, this product meets all Class 2 requirements. Otherwise,
all Class 1 requirements are met for copper ports.
• If the unit contains copper ports, the IEC 1613 conformance is Class 1, during which disturbance
errors may occur but recovery is automatic.
• If the unit contains all fiber ports, the IEC 1613 conformance is Class 2, during which no disturbance
errors will occur.
Test
Description
Test Levels
Severity Levels
Enclosure Contact
+/- 8 kV
4
IEC 61000-4-2
ESD
Enclosure Air
+/- 15 kV
4
IEC 61000-4-3
Radiated RFI
Enclosure ports
20 V/m
Note
a
Signal ports
+/- 4 kV @ 2.5 kHz
Note
a
DC Power ports
+/- 4 kV
4
AC Power ports
+/- 4 kV
4
IEC 61000-4-4
Burst (Fast Transient)
Earth ground ports
b
+/- 4 kV
4
Signal ports
+/- 4 kV line-to-earth,
+/- 2 kV line-to-line
4
DC Power ports
+/- 2 kV line-to-earth,
+/- 1 kV line-to-line
3
IEC 61000-4-5
Surge
AC Power ports
+/- 4 kV line-to-earth,
+/- 2 kV line-to-line
4
Signal ports
D.C Power ports
AC Power ports
IEC 61000-4-6
Induced (Conducted) RFI
Earth ground ports
10 V
3
IEC 61000-4-8
Magnetic Field
Enclosure ports
40 A/m continuous,
1000 A/m for 1 s
DC Power ports
30% for 0.1 s, 60% for
0.1 s, 100% for 0.05 s
IEC 61000-4-29
30% for 1 period,
60% for 50 periods
IEC 61000-4-11
Voltage Dips & Interrupts
AC Power ports
100% for 5 periods,
100% for 50 periods
2